Review



oim analysis software  (Gatan Inc)


Bioz Verified Symbol Gatan Inc is a verified supplier
Bioz Manufacturer Symbol Gatan Inc manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 96

    Structured Review

    Gatan Inc oim analysis software
    Oim Analysis Software, supplied by Gatan Inc, used in various techniques. Bioz Stars score: 96/100, based on 1218 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/oim+software/OIM+Analysis/10__3390_slash_jmmp10030094-86-40-43
    Average 96 stars, based on 1218 article reviews
    oim analysis software - by Bioz Stars, 2026-10
    96/100 stars

    Images

    Related Articles

    Software:

    Article Title: Improving Mechanical Properties of 18%Mn TWIP Steels by Cold Rolling and Annealing
    Article Snippet: .. The OIM software (TSL OIM Analysis 6.2) (EDAX, Inc., Mahwah, NJ, USA) was used for evaluation of the mean grain size (D). ..

    Article Title: Temperature Effect on Deformation Mechanisms and Mechanical Properties of Welded High-Mn Steels for Cryogenic Applications
    Article Snippet: .. And then, chemical etching was performed using a 5% nital solution for 30 s. For the microstructure of a deformed tensile specimen, electron backscatter diffraction (EBSD, Oxford instrument, Oxford, UK) analysis was investigated with OIM software (EDAX, TSL OIM Analysis 7, Redwood Shore, CA, USA) by a field emission scanning electron microscope (FE-SEM, Hitachi, Tokyo, Japan) machine. ..

    Article Title: Effect of Heat Treatment on Microstructure and Mechanical Properties of High-Strength Steel for in Hot Forging Products
    Article Snippet: The microstructure of specimen were observed using optical microscopy (OM) and FE-SEM HITACHI S-4800 (HITACHI, Tokyo, Japan). .. Electron backscattering diffraction (EBSD) used a JEOL FE-SEM 7200F (JEOL, 7200F, Tyoko, Japan) with OIM software (EDAX, OIM v7.2.1 Orientation Imaging Microscopy, Mahwah, NJ, United States). ..

    Article Title: The mechanism for annealing-induced ductile to brittle transition in a high-temperature titanium alloy and its mitigation
    Article Snippet: By investigating the relation between microstructure evolution and tensile responses of a BTi6431S alloy at room temperature and 700 C, this study finds an annealing-induced ductile-to-brittle transition phenomenon in the near-α titanium alloy.. The high strength of the as-received BTi6431S alloy is rooted in the high dislocation density and collective dislocation behavior in the α phase.. However, after annealing at 650 C, the alloy exhibits brittle fracture at room temperature.

    Article Title: Relationship between Microstructure and Corrodibility of Local Dry Underwater Laser Welded 304 Stainless Steel
    Article Snippet: .. The diverse origins of the EBSD parameters were studied using the OIM software (EDAX, TSL). ..

    Article Title: Temperature Effect on Deformation Mechanisms and Mechanical Properties of Welded High-Mn Steels for Cryogenic Applications.
    Article Snippet: .. And then, chemical etching was performed using a 5% nital solution for 30 s. For the microstructure of a deformed tensile specimen, electron backscatter diffraction (EBSD, Oxford instrument, Materials 2024, 17, 4159 4 of 18 Oxford, UK) analysis was investigated with OIM software (EDAX, TSL OIM Analysis 7, Redwood Shore, CA, USA) by a field emission scanning electron microscope (FE-SEM, Hitachi, Tokyo, Japan) machine. ..

    Article Title: Hierarchical Microstructure–Mechanical Property Correlations in Superior Strength 5 wt% Cr Cold-Work Tool Steel Manufactured by Direct Energy Deposition
    Article Snippet: The distribution of alloy elements in the specimens was measured using an electron probe micro-analyzer (EPMA, JXA-8530F Plus, JEOL, Tokyo, Japan). .. The phase and misorientation distributions of the initial and deformed samples were analyzed by electron backscatter diffraction (EBSD, Nordlys nano-detector, Oxford, UK) at an accelerating voltage of 20 kV, and OIM software (TSL OIM analysis 8, EDAX, Mahwah, NJ, USA) was used for data analysis. ..

    Article Title: Hierarchical Microstructure-Mechanical Property Correlations in Superior Strength 5 wt% Cr Cold-Work Tool Steel Manufactured by Direct Energy Deposition.
    Article Snippet: The distribution of alloy elements in the specimens was measured using an electron probe micro-analyzer (EPMA, JXA-8530F Plus, JEOL, Tokyo, Japan). .. The phase and misorientation distributions of the initial and deformed samples were analyzed by electron backscatter diffraction (EBSD, Nordlys nano-detector, Oxford, UK) at an accelerating voltage of 20 kV, and OIM software (TSL OIM analysis 8, EDAX, Mahwah, NJ, USA) was used for data analysis. ..

    Microscopy:

    Article Title: Temperature Effect on Deformation Mechanisms and Mechanical Properties of Welded High-Mn Steels for Cryogenic Applications
    Article Snippet: .. And then, chemical etching was performed using a 5% nital solution for 30 s. For the microstructure of a deformed tensile specimen, electron backscatter diffraction (EBSD, Oxford instrument, Oxford, UK) analysis was investigated with OIM software (EDAX, TSL OIM Analysis 7, Redwood Shore, CA, USA) by a field emission scanning electron microscope (FE-SEM, Hitachi, Tokyo, Japan) machine. ..

    Article Title: Effect of Heat Treatment on Microstructure and Mechanical Properties of High-Strength Steel for in Hot Forging Products
    Article Snippet: The microstructure of specimen were observed using optical microscopy (OM) and FE-SEM HITACHI S-4800 (HITACHI, Tokyo, Japan). .. Electron backscattering diffraction (EBSD) used a JEOL FE-SEM 7200F (JEOL, 7200F, Tyoko, Japan) with OIM software (EDAX, OIM v7.2.1 Orientation Imaging Microscopy, Mahwah, NJ, United States). ..

    Article Title: Temperature Effect on Deformation Mechanisms and Mechanical Properties of Welded High-Mn Steels for Cryogenic Applications.
    Article Snippet: .. And then, chemical etching was performed using a 5% nital solution for 30 s. For the microstructure of a deformed tensile specimen, electron backscatter diffraction (EBSD, Oxford instrument, Materials 2024, 17, 4159 4 of 18 Oxford, UK) analysis was investigated with OIM software (EDAX, TSL OIM Analysis 7, Redwood Shore, CA, USA) by a field emission scanning electron microscope (FE-SEM, Hitachi, Tokyo, Japan) machine. ..

    Imaging:

    Article Title: Effect of Heat Treatment on Microstructure and Mechanical Properties of High-Strength Steel for in Hot Forging Products
    Article Snippet: The microstructure of specimen were observed using optical microscopy (OM) and FE-SEM HITACHI S-4800 (HITACHI, Tokyo, Japan). .. Electron backscattering diffraction (EBSD) used a JEOL FE-SEM 7200F (JEOL, 7200F, Tyoko, Japan) with OIM software (EDAX, OIM v7.2.1 Orientation Imaging Microscopy, Mahwah, NJ, United States). ..



    Similar Products

    96
    Gatan Inc oim analysis software
    Oim Analysis Software, supplied by Gatan Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/oim+software/OIM+Analysis/10__3390_slash_jmmp10030094-86-40-43
    Average 96 stars, based on 1 article reviews
    oim analysis software - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    96
    Gatan Inc tsl oim analysis 5 2 software package
    Tsl Oim Analysis 5 2 Software Package, supplied by Gatan Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/oim+software/OIM+Analysis/10__3390_slash_met16030287-74-6-12
    Average 96 stars, based on 1 article reviews
    tsl oim analysis 5 2 software package - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    96
    Gatan Inc oim analysis 9 software
    Oim Analysis 9 Software, supplied by Gatan Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/oim+software/OIM+Analysis/10__1007_slash_s11661___026___08139___6-73-45-44
    Average 96 stars, based on 1 article reviews
    oim analysis 9 software - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    96
    Gatan Inc oim analysis software suite
    Oim Analysis Software Suite, supplied by Gatan Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/oim+software/OIM+Analysis/pm41644543-330-6-5
    Average 96 stars, based on 1 article reviews
    oim analysis software suite - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    96
    Gatan Inc tls oim analysis 8 0 software
    Tls Oim Analysis 8 0 Software, supplied by Gatan Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/oim+software/OIM+Analysis/pmc12787245-139-0-6
    Average 96 stars, based on 1 article reviews
    tls oim analysis 8 0 software - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    96
    Gatan Inc oim v8 5 analysis software
    Oim V8 5 Analysis Software, supplied by Gatan Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/oim+software/OIM+Analysis/pm41374205-85-40-45
    Average 96 stars, based on 1 article reviews
    oim v8 5 analysis software - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    96
    Gatan Inc orientation imaging microscopy oim software
    Orientation Imaging Microscopy Oim Software, supplied by Gatan Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/oim+software/OIM+Analysis/10__1016_slash_j__jmrt__2025__12__245-86-8-14
    Average 96 stars, based on 1 article reviews
    orientation imaging microscopy oim software - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    96
    Gatan Inc oim analysis 8 software
    Oim Analysis 8 Software, supplied by Gatan Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/oim+software/OIM+Analysis/10__1016_slash_j__matdes__2025__115400-53-7-11
    Average 96 stars, based on 1 article reviews
    oim analysis 8 software - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    Image Search Results